TAE Thermostat

1. Use

TAE .. is an explosion-proof thermostat, which is designed as two-state controller and in connection with INTERTEC electrical heater can regulate preset temperature inside a box.
Thermostat can be different switching or for monitoring applications.
TAE AM version contains alarm: if temperature in the box is lower than 7 °C, then the NC contact triggers an alarm. After reaching 16 °C, the contact closes again.

2. Advantages

  • Robust aluminium construction
  • Fully sealed with silicone
  • Relatively accurate if the thermostat is place on the heater
  • Storage and working temperatures range from -50°C to +180°C

3. Measuring accuracy

The air temperature in the heated cabinet may not be the same everywhere. Depending on the difference between the indoor and outdoor temperature (delta T), the insulation, the heater configuration and installed equipment, etc., the temperature (e.g., between the top and the bottom) may fluctuate by 10 degrees or more.
For precise instrument temperature control, a proportional controller with a temperature sensor such as INTERTEC TC ATEX D .... is used
If the thermal feedback TAE is installed on the heater (see Section 5 Installation), it provides the derivative control characteristics while maintaining the temperature at the center of the enclosure at the stated value of accuracy approx.. +/- 3 ° C.

4. Types a technical parameters

Number in type marking represents the desired switching value in °C.

TAE (temperature regulator)
Type Closes at (°C) Opens at (°C)
TAE -15 -15 -5
TAE -10 -10 0
TAE 10 10 18
TAE 20 20 28
TAE 30 30 38
TAE 40 40 48
Option other values upon request


TAE AM (alarm)
Type Closes at (°C)  Opens at (°C)
 TAE -15 AM  -15  -5
 TAE 5 AM  5  16
 TAE 20 AM  20  26
 TAE 30 AM  30  40


Dimensions 90 x 24 mm
Nominal voltage Max. 250V, higher nominal voltage upon request
Hysteresis  +/- 3°C
Maximum nominal current 10 A
Storage and working temperature -50°C - +180°C
Protection IP 68
Material: seawater resistant aluminium, black elox
Explosion protection  Ex II2G Eex d IIC T6
II2D IP68 T80°C
EC certificate  PTB03ATEX 1136X

5. Installation

TAE thermostat has one mounting hole.
The supplied M6x25 screw or smaller pass-through bolt can be used for mounting.
For use as a temperature regulator the TAE with defined temperature should be installed on INTERTEC heater
.

5.1 - Installation of TAE thermostat on MULTITHERM heater

Heaters like e.g. MULTITHERM, are equipped slit fitting rails in the rib profile.
 - Slightly loosen the TAE thermostat nut / screw

 - Insert the screw head into one rib profile slot.
(The length of PTFE remains outside)
 -
Carefully tighten by turning the TAE thermostat.

5.2 - Installation of TAE thermostat on VARITHERM heater

On both sides of the VARITHERM are M6 holes.
 - Turn the threaded rod provided with the screw sleeve of VARITHERM approx.. heater 5 mm into one of these threaded holes
 - Put on the white PTFE spacer
 - Attach the end of the threaded rod to the thread of the M6 TAE thermostat and tighten it carefully by turning the thermostat

6. Wiring diagram


Files to download

Certificates

Declarations of Conformity

This website uses cookies to ensure you get the best experience on our website.