Schuch - nD866 / nD867 Linear lights LED

For lighting of hazardous areas zone 2 and 22, the product series ExeLED 2 is the perfect choice. It excels with its innovative encapsulated LED modules, the sandwich design of diffuser and reflector to protect the LED modules from mechanical and electrostatic damage, as well as homogeneous illumination and excellent glare limitation because of the frosted diffuser (version "F"). High-quality LED and electronic control gears guarantee high efficiency and an extremely long service life. And with the FastFix quick mounting system, installation of the light fittings is easy and saves time.

For escape routes and work areas with special risks, reliability of illumination is essential in the event of a failure of the general lighting system to allow safe exit of the affected area. In hazardous areas zone 2 and 22, the explosion-protected LED emergency light fittings with single battery of product series ExeLED 2 N provide this with great reliability and noticeably high efficiency. Through automatic self-monitoring with regular function and duration tests, as well as the optical indicator of test results, it is possible to ensure that the light fittings immediately provide light with maximum luminous flux in the event of a power outage.

  • nD866 - w/0 battery
  • nD867 -
    • e864 - battery life up to 3hrs.

 

Marking Power cons. / Luminous flux Ambient temperature Weight [kg]
nD866F 06L22 15 W / 2 170 lm -30°C ... +40°C 3,3
nD866F 06L42 28 W / 4 120 lm -30°C ... +40°C 3,4
nD866F 06L60
40 W / 5 700 lm -30°C ... +40°C 3,4
nD866F 12L42 28 W / 4 360 lm -30°C ... +40°C 5,4
nD866F 12L60 40 W / 6 020 lm -30°C ... +40°C 5,4
nD866F 12L85 54 W / 8 620 lm -30°C ... +40°C 5,5

 

 

 

 

 

 

 

Marking Power cons. / Luminous flux Battery life Ambient temperature Weight [kg]
nD867F 12L42/1/4
29 W / 4 360 lm 1h -30°C ... +40°C 4,4
nD867F 12L60/1/4
41 W / 6 020 lm 1h -30°C ... +40°C 6,3
nD867F 12L42/3/4
29 W / 4 360 lm  3h -30°C ... +40°C 6,3
nD867F 12L60/3/4
41 W / 6 020 lm  3h -30°C ... +40°C 6,3



Technical data

Basic overview

  • Explosion protection (1) II 3 G Ex ec IIC T4 Gc
  • Explosion protection (2) II 3 D Ex tc IIIC T80°C Dc
  • Zone 2, 22
  • Ingress protection IP66
  • Ambient temperature -30°C ... +55°C
  • Material GRP body, polycarbonate cover

Electrical data

  • Nominal voltage 220-240V AC (50/60Hz)
Files to download