M.x. Threaded line bushings
Line bushings are used for connecting of electrical respectively optical circuits of two separate parts of ex equipment, usually between instrument part of flameproof enclosure and explosion-protected terminals part, eventually between two flameproof enclosures. Explosion-proof line bushings type M.x. are designed as Ex component (or stand-alone Ex device), intended for installation in flameproof enclosures of explosion-proof electrical devices. Line bushings casing creates together with the wall of flameproof enclosure a flameproof enclosure threaded joint
Specific make of line bushings is given by technical specification on the basis of which we will propose the optimal solution.
M (1) K (2) x (3) (4) / (5)
- (1) Thread size - 10, 12, 16, 24, 25, 32, 33, 36, 38, 42
- (2) Cables quantity - 1 to 45
- (3) Impedance - 50, 75, 95 Ω
- (4) Cable length L1 [mm] (hexagon side)
- (5) Cable length L2 [mm] (thread side)
Order code example: M24K2x50 200/200
M (1) V (2) x (3) (4) (5) / (6)
- (1) Thread size - 10, 12, 16, 24, 25, 32, 33, 36, 38, 42
- (2) Conductor quantity - 1 to 45
- (3) Conductor cross-section - 0,35 to 70 mm2
- (4) Conductor color and quantity
- (5) Cable length L1 [mm] (hexagon side)
- (6) Cable length L2 [mm] (thread side)
Order code example: M36V7x2,5 4bk+3bu 300/500
M (1) O (2) x (3) (4) / (5)
- (1) Thread size - 10, 12, 16, 24, 25, 32, 33, 36, 38, 42
- (2) Cables quantity - 1 to 45
- (3) Thread type - 9/125, 50/125, 62.5/125, 100/125, 200/300 μm
- (4) Cable length L1 [mm] (hexagon side)
- (5) Cable length L2 [mm] (thread side)
Order code example: M36O2x9/125 150/300
M (1) P (2) x (3) (4) / (5)
- (1) Thread size - 10, 12, 16, 24, 25, 32, 33, 36, 38, 42
- (2) Flat conductor quantity - 4 to 48
- (3) Conductor cross-section - 28, 26, 24, 20, 18 AWG
- (4) Cable length L1 [mm] (hexagon side)
- (5) Cable length L2 [mm] (thread side)
Order code example: M42P48x18 200/200
Basic overview
- Explosion protection I M2 Ex db (eb) I Mb / II 2G Ex db (eb) IIC Tx Gb
- Zone 1, 2 - SNM 1, 2
- Ambient temperature -60°C up to +115°C
- * This is the maximum range of operating temperatures for all types of explosion-proof bushings. The actual range is given by the type of wires or cables used.
Datasheets
Threaded line bushings_M.x._CZ | 62 KB | Download | |
Threaded line bushings_M.x._EN | 61 KB | Download |
User manuals
User manual_M.x._CZ
Threaded line bushings - Ex devices
|
379 KB | Download | |
User manual_D.x._M.x._CZ
Cylindrical line bushings - Ex components
|
266 KB | Download |
Certificates
FTZÚ 10 ATEX 0022X_M.x._CZ
Threaded line bushings - Ex devices
|
6928 KB | Download | |
FTZÚ 10 ATEX 0022X_M.x._EN
Threaded line bushings - Ex devices
|
6839 KB | Download | |
FTZÚ 07 ATEX 0019U_D.x._CZ
Cylindrical line bushings - Ex components
|
2890 KB | Download | |
FTZÚ 07 ATEX 0019U_D.x._EN
Cylindrical line bushings - Ex components
|
2824 KB | Download |
Declarations of Conformity
Declaration of conformity_M.x.
Threaded line bushings - Ex devices
|
90 KB | Download | |
Certificate of Conformity_D.x._M.x.
Cylindrical and threaded line bushings - Ex components
|
84 KB | Download |