Explosion-Proof Air Conditioners

Explosion-Proof Air Conditioners

Features:

-           Based on Toshiba systems
-           ATEX certification
-           Suitable for use in Zone 2
-           Cooling and heating capacity from 2.5 kW to 14 kW
-           Operating temperature range from -27°C to +52°C
-           Available in industrial, compact, and lightweight industrial models
-           Optional additional protective coating
-           Combination of explosion-proof and standard units possible
-           ATEX certification:     II 3 G Ex ec h ic mc IIC T3 Gc
                                           II 3 G Ex ec h ic IIC T4 Gc

 

Description:

Explosion-proof air conditioning units are designed to safely provide the required climate in areas where gas, vapor, or mist leaks could create an explosive atmosphere (Zone 2). These units are widely used in office spaces, offshore temporary accommodations, crane cabins, and for the storage of chemicals and flammable substances.


Depending on the required capacity and application, you can choose from wall-mounted, ceiling-mounted, cassette, or ducted models. Multi-split versions, where multiple indoor units are combined with a single outdoor unit, are also common. The air conditioners are explosion-proof and certified according to the European Directive 2014/34/EU (ATEX 114) with CE marking.

   Depending on the required capacity and application, you can choose from wall-mounted, ceiling-mounted, cassette, or ducted models. Multi-split versions, where multiple indoor units are combined with a single outdoor unit, are also common. The air conditioners are explosion-proof and certified according to the European Directive 2014/34/EU (ATEX 114) with CE marking. .

-          For installation in corrosive environments, outdoor units can be provided with an additional protective coating.

Main Categories:

Industrial use, High and Low Temperatures:

Industrial units are designed for continuous operation in environments such as manufacturing facilities, laboratories, and measurement rooms. These systems are equipped with a more powerful compressor, ensuring high energy efficiency and extreme reliability.

-          Based on Toshiba RAV-GP outdoor unit series;
-          Pipe lengths up to 50 meters for systems up to 10 kW and up to 75 meters for systems 10 kW and above;
-          Cooling operation in ambient temperatures from -15°C to +52°C and heating from -27°C;
-          Wall-mounted models come with an infrared remote control; ceiling, ducted, and cassette models feature a wired remote control;
-          Refrigerant: R32

Type number Power Consumption (Cooling) [kW] Power Consumption (Heating) [kW] Supply Voltage [V AC] Frequency
[Hz]
Fuse Rating [A] Electrical Power Supply [kW] Airflow
[m3 / hodina]
Model
AR-051/0511 5,0 5,6 230 50 16 1,43 680 / 960 Wall
AR-051/0512 5,0 5,6 230 50 16 1,39 540 / 900 Ceiling
AR-051/0513 5,0 5,6 230 50 16 1,61 480 / 800 Duct
AR-051/0514 5,0 5,0 230 50 16 1,30 780 / 1.050 Cassette
AR-051/0711 7,1 8,0 230 50 20 2,25 680 / 1.040 Wall
AR-051/0712 7,1 8,0 230 50 20 1,80 750 / 1.410 Ceiling
AR-051/0713 7,1 8,0 230 50 16 1,85 750 / 1.200 Duct
AR-051/0714 7,1 8,0 230 50 20 1,77 810 / 1.230 Cassette
AR-051/1011 10,0 11,2 230 50 20 3,13 1.180 / 1.610 Wall
AR-051/1012 10,0 11,2 230 50 25 2,38 1.020 / 1.860 Ceiling
AR-051/1013 10,0 11,2 230 50 20 2,73 1.260 / 2.100 Duct
AR-051/1014 10,0 11,2 230 50 20 2,18 1.170 / 2.010 Cassette
AR-051/1212 12,5 14,0 230 50 25 3,59 1.200 / 2.040 Ceiling
AR-051/1213 12,5 14,0 230 50 25 3,63 1.260 / 2.100 Duct
AR-051/1214 12,5 14,0 230 50 25 3,21 1.230 / 2.100 Cassette
AR-051/1422 14,0 16,0 400 50 3 x 16 4,60 1.200 / 2.040 Ceiling
AR-051/1423 14,0 16,0 400 50 3 x 16 4,57 1.260 / 2.100 Duct
AR-051/1424 14,0 16,0 400 50 3 x 16 4,34 1.260 / 2.130 Cassette

Optional Accessories:

-          Wired remote control for wall-mounted models as a replacement for the infrared remote control;
-          Additional surface treatment of aluminum fins, copper pipes, and sheet metal with Blygold PolualXT coating;
-          Explosion-proof protective switch.

 

Industrial use, compact Design:

Compact industrial units are designed for continuous operation and are particularly suitable for use in mobile installations, container applications, and crane cabins.

-          Based on the Toshiba RAV-GM outdoor unit series;
-          Some models support a power grid frequency of 50/60 Hz;
-          Cooling operation in ambient temperatures from -15°C to +46°C and heating from -15°C;
-          Wall-mounted models come with an infrared remote control;
-          Ceiling, ducted, and cassette models feature a wired remote control;
-          Refrigerant: R32

Type number Power Consumption (Cooling) [kW] Power Consumption (Heating) [kW] Supply Voltage [V AC] Frequency
[Hz]
Fuse Rating [A] Electrical Power Supply [kW] Airflow
[m3 / hodina]
Model
AR-051/0211 C 2,5 3,4 230 50 / 60 16 0,85 450 / 670 Wall
AR-051/0311 C 3,6 4,0 230 50 / 60 16 1,13 450 / 700 Wall
AR-051/0312 C 3,6 4,0 230 50 / 60 16 0,83 540 / 900 Ceiling
AR-051/0511 C 5,0 5,3 230 50 / 60 16 1,66 680 / 960 Wall
AR-051/0512 C 5,0 5,3 230 50 / 60 16 1,61 540 / 900 Ceiling
AR-051/0513 C 5,0 5,3 230 50 / 60 16 1,83 480 / 800 Duct
AR-051/0514 C 5,0 5,3 230 50 / 60 16 1,56 780 / 1.050 Cassette
AR-051/0711 C 6,7 7,7 230 50 16 2,30 680 / 1.040 Wall
                 
AR-051/0712 C 6,7 7,7 230 50 16 2,06 750 / 1.410 Ceiling
AR-051/0713 C 6,7 7,7 230 50 16 2,04 750 / 1.200 Duct
                 
AR-051/0714 C 6,7 7,7 230 50 16 1,99 810 / 1.230 Cassette
AR-051/0811 C 8,0 8,6 230 50 16 2,67 680 / 1.180 Wall
AR-051/0812 C 8,0 8,6 230 50 16 2,38 900 / 1.600 Ceiling
AR-051/0813 C 8,0 8,6 230 50 16 2,39 1.000 / 1.700 Duct
                 
AR-051/0814 C 8,0 8,6 230 50 16 2,29 900 / 1.600 Cassette
AR-051/1011 C 9,5 11,2 230 50 20 2,95 1.180 / 1.610 Wall
AR-051/1012 C 9,5 11,2 230 50 20 2,86 1.020 / 1.860 Ceiling
AR-051/1013 C 9,5 11,2 230 50 20 2,60 1.260 / 2.100 Duct
AR-051/1014 C 9,5 11,2 230 50 20 2,86 1.170 / 2.010 Cassette
AR-051/1021 C 9,5 11,2 400 50 3 x 16 3,38 1.180 / 1.610 Wall
AR-051/1022 C 9,5 11,2 400 50 3 x 16 2,83 1.020 / 1.860 Ceiling
AR-051/1023 C 9,5 11,2 400 50 3 x 16 2,87 1.260 / 2.100 Duct
AR-051/1024 C 9,5 11,2 400 50 3 x 16 2,82 1.170 / 2.010 Cassette
AR-051/1212 C 12,1 13,0 230 50 25 4,01 1.200 / 2.040 Ceiling
AR-051/1213 C 12,1 13,0 230 50 25 4,01 1.260 / 2.100 Duct
AR-051/1214 C 12,1 13,0 230 50 25 3,88 1.230 / 2.100 Cassette
AR-051/1222 C 12,1 13,0 400 50 3 x 16 3,94 1.200 / 2.040 Ceiling
AR-051/1223 C 12,1 13,0 400 50 3 x 16 3,94 1.260 / 2.100 Duct
AR-051/1224 C 12,1 13,0 400 50 3 x 16 3,81 1.230 / 2.100 Cassette
AR-051/1422 C 14,0 16,0 400 50 3 x 16 4,94 1.260 / 2.040 Ceiling
AR-051/1423 C 14,0 16,0 400 50 3 x 16 5,14 1.260 / 2.100 Duct
AR-051/1424 C 14,0 16,0 400 50 3 x 16 4,92 1.260 / 2.130 Cassette

Optional Accessories:

-          Wired remote control for wall-mounted models as a replacement for the infrared remote control;
-          Additional surface treatment of aluminum fins, copper pipes, and sheet metal with Blygold PolualXT coating;
-          Explosion-proof operation switch

 

Light industrial use, Especially for 60Hz Applications:

The light industrial units are designed for a mains frequency of 50 and 60 Hz.

-          Based on the Toshiba RAV-GV series;
-          Mains frequency 50 / 60 Hz supported by the manufacturer;
-          Cooling operation from -15°C to +46°C ambient temperature and heating from -15°C;
-          Wall-mounted model with infrared remote control; ceiling, ducted, and cassette models with a wired remote control;
-          Refrigerant: R32

Type number Power Consumption (Cooling) [kW] Power Consumption (Heating) [kW] Supply Voltage [V AC] Frequency
[Hz]
Fuse Rating [A] Electrical Power Supply [kW] Airflow
[m3 / hodina]
Model
AR-051/0511 L 5,0 5,3 230 50 / 60 16 1,50 680 / 960 Wall
AR-051/0512 L 5,0 5,3 230 50 / 60 16 1,50 540 / 900 Ceiling
AR-051/0513 L 5,0 5,3 230 50 / 60 16 1,85 480 / 800 Duct
AR-051/0514 L 5,0 5,3 230 50 / 60 16 1,60 780 / 1050 Cassette
AR-051/0711 L 6,7 7,0 230 50 / 60 16 2,20 680 / 1.040 Wall
AR-051/0712 L 6,7 7,0 230 50 / 60 16 2,20 750 / 1.410 Ceiling
AR-051/0713 L 6,7 7,0 230 50 / 60 16 2,33 750 / 1.200 Duct
AR-051/0714 L 6,7 7,0 230 50 / 60 16 2,20 810 / 1.230 Cassette
                 
AR-051/1011 L 9,5 10,0 230 50 / 60 20 3,80 1.180 / 1.610 Wall
AR-051/1012 L 9,5 10,0 230 50 / 60 20 3,80 1.020 / 1.860 Ceiling
                 
AR-051/1013 L 9,5 10,0 230 50 / 60 20 3,17 1.260 / 2.100 Duct
AR-051/1014 L 9,5 10,0 230 50 / 60 20 3,15 1.170 / 2.010 Cassette
AR-051/1021 L 9,5 10,0 400 50 / 60 3 x 16 3,40 1.180 / 1.610 Wall
AR-051/1022 L 9,5 10,0 400 50 / 60 3 x 16 3,40 1.020 / 1.860 Ceiling
AR-051/1023 L 9,5 10,0 400 50 / 60 3 x 16 3,10 1.260 / 2.100 Duct
AR-051/1024 L 9,5 10,0 400 50 / 60 3 x 16 3,15 1.170 / 2.010 Cassette
AR-051/1212 L 11,5 12,1 230 50 / 6

 