CP Multitherm D.A
CP MULTITHERM is an electrical heater which is designed for convection air heating inside a box.
1. Use
Heating of boxes in potentially explosive atmospheres. Designed for:
- Frost protection
- Condensation protection
- Vertical installation
2. Advantages
- Short lead times
- Vertical design allows optimal installation close to heated device in the box
- The frost protection thermostat (TS) is built-in the power cable as standard
- High thermal output due to special black aluminium construction
3. Description
CP MULTITHERM is an electrical heater which is designed for convection air heating inside a box.
Wherever possible, heating with temperature class T3 can be used.
The temperature limiter is built-in directly in the power cable, allowing disconnection from the power supply in the event of a technical fault or excessive heat from surrounding heat sources. The temperature limiter may only be repaired at the factory. For reasons of safety, the Heater may only operate under conditions where it is ensured that the limiting temperature of the limiter is not exceeded:
- TS, TAE or TC thermostats shut off the Heater if the cabinet temperature is high
- To ensure sufficient convection, minimal distances must be observed. fig. below (point 7) and at the same time it is necessary to avoid covering of the heater's ribs.
4. Technical parameters
Explosion protection | II 2 G Ex dm IIC T3, T4, T5, T6 II 2 D Ex tDmD A21 IP65, T135°C, T200°C |
EC certificate | PTB 02 ATEX 1041 X |
Ingress protection | IP 68 |
Operating temperature | -50°C up to 180°C |
Nominal voltage | 230V AC (220-240 V Ac) |
Supply cable | EWKF 3x1,5 mm² Ø8,8mm |
Dimensions (W x D ) | 80 x 80 mm |
Length of supply cable | 1 m |
Material | Seawater-proof aluminium, black, anodized |
All INTERTEC explosion-proof heaters can be delivered according to American NEC standards (CSA/NRTL/FM/UL) and are available also in cheaper safe area design.
5. Variants
CP Multitherm DNA | 50 T4 | 75 T4 | 100T3* | 150T3 |
Temperature class | T4 | T4 | T3 | T3 |
Nominal power output [W] | 50 | 75 | 100 | 150 |
Height | 155 mm |
CP Multitherm DPA | 100 T4 | 200 T3 | 250 T3 |
Temperature class | T4 | T3 | T3 |
Nominal power output [W] | 100 | 200 | 250 |
Height | 225 mm |
* This Heater type is also available with the TS40 protective thermostat integrated into the supply cable to keep the temperature up to 40 ° C. Ambient temperature control must be carried out using an additional TAE thermostat or TC temperature controller. (other types upon request)
6. Options
TS 40 | Protective thermostat |
AM | Failure alarm opening at < 5 °C |
3M | Supply cable length 3m |
120 V, 24 V | Nominal voltage 120V AC, 24 V AC/DC |
250 V | Nominal voltage 250V AC (245-265 V AC) |
Ordering example: CP MULTITHERM DPA 250 T3 TS 3M
7. Installation and minimum clearances
The mounting bracket supplied with the heating is very versatile. Mounting accessories such as bolts and nuts are included.
8. Wiring diagram
Certificates
![]() |
6550 KB | Download | |
![]() |
1674 KB | Download |
Declarations of Conformity
![]() |
844 KB | Download |