CP Microtherm DNA
CP MICROTHERM is a variable electrical heater, which is designed for convection air heating inside a box. Microtherm is a suitable choice if the space does not allow the installation of a larger Heater model such as e.g. CP MULTITHERM.
1. Use
Heating of protection boxes in potentially explosive atmospheres, designed for:
- Frost protection
- Condensation protection
- Vertical installation
2. Advantages
- Very narrow Heater shape
- Vertical design allows for optimal installation adjacent to the apparatus to be heated in the box
- Thermostat (TS) for frost protection built-in the power cable as standard
- High thermal output due to special black aluminium construction
3. Description
CP MICROTHERM is a variable electrical heater, which is designed for convection air heating inside a box. Wherever possible, heating with temperature class T3 can be used.
Wherever possible, heating with temperature class T3 can be used.
The temperature limiter is built-in directly in the power cable, allowing disconnection from the power supply in the event of a technical fault or excessive heat from surrounding heat sources. The temperature limiter may only be repaired at the factory. For reasons of safety, the Heater may only operate under conditions where it is ensured that the limiting temperature of the limiter is not exceeded:
- TS, TAE or TC thermostats shut off the Heater if the cabinet temperature is high
- To ensure sufficient convection, minimal distances must be observed. fig. below (point 7) and at the same time it is necessary to avoid covering of the Heater's ribs.
4. Technical parameters
Explosion protection | II 2 G Ex dm IIC T3, T4, T5, T6 II 2 D Ex tDmD A21 IP65 T135°C, T200°C |
EC certificate | PTB 02 ATEX 1041 X |
Ingress protection | IP 68 |
Operating temperature | -50°C up to 180°C |
Nominal voltage | 230V AC (220-240 V AC) |
Supply cable | EWKF 3x1,5 mm² Ø8,8mm |
Dimensions (W x D x H) | 50 x 50x 155mm |
Length of supply cable | 1 m |
Material | seawater-proof aluminium, black, anodized |
All INTERTEC explosion-proof heaters can be delivered according to American NEC standards (CSA/NRTL/FM/UL) and are available also in cheaper safe area design.
5. Variants
CP Microtherm DNA | 25 T4 | 40 T4 | 75 T3 |
Temperature class | T4 | T4 | T3 |
Nominal power output | 25 | 40 | 75 |
(other types upon request)
6. Options
TS | Ambient frost protection thermostat |
AM | Failure alarm opening at < 5 °C |
3M | Supply cable length 3m |
120 V | Nominal voltage 120V AC |
250 V | Nominal voltage 250V AC |
Ordering example: CP MICROTHERM DNA 75 T3 TS 3M
7. Installation and minimum clearances
8. Wiring diagram
Certificates
![]() |
6550 KB | Download | |
![]() |
1674 KB | Download |
Declarations of Conformity
![]() |
844 KB | Download |