CP Megatherm

CP MEGATHERM is an electric ribbed heater designed for convection air heating inside a box.

1. Use

Heating of boxes in potentially explosive atmospheres. Designed for:

  • Frost protection
  • Condensation protection
  • Mostly for vertical installation

2. Advantages

  • Vertical design allows optimal installation close to heated device in the box
  • Horizontal installation is possible
  • Thermostat for frost protection in the supply cable (TS option)
  • High heat transfer through a large area of black aluminium ribs

3. Description

CP MEGATHERM is an electric ribbed heater designed for convection air heating inside a box.

The temperature class limiter is integrated into the heating block core and disconnects the power supply in case of a technical fault or overheating due to an external heat source. This limiter can only be repaired at the factory.
For safe operation, the heater must be operated under conditions that ensure that the heater is not exposed to temperatures higher than those specified on the limiter:

  • TS, TAE or TC thermostats shut off the heater if the cabinet temperature is high
  • To ensure sufficient convection, minimal distances must be observed. fig. below (point 7) and at the same time it is necessary to avoid covering of the heater's ribs.

For any specific applications requiring high temperature maintenance we will be pleased to select the suitable combination of heater and controller.

A temperature indicator shows potential problems and failures at an early stage (e.g. incorrect installation). Please check the application if more than 3 fields have irreversibly changed to black!

 

4. Technical parameters

Explosion protection  II 2 G Ex dm IIC T3, T4, T5, T6
II 2 D Ex tDmD A21 IP65, T135°C, T200°C
Ex certificate  PTB 02 ATEX 1041 X
Ingress protection  IP 68
Operating temperature  -50°C up to 180°C
 Nominal voltage  230V AC (220-240 V Ac)
 Supply cable  EWKF 3x1,5 mm² Ø8,5mm
Dimensions (L x W )  229 x 60mm
 Length of supply cable  1 m
 Material  Seawater-proof aluminium, black, anodized

 All INTERTEC explosion-proof heaters can be delivered according to American NEC standards (CSA/NRTL/FM/UL) and are available also in cheaper safe area design.

5. Variants

5.1 - frost protection

CP Megatherm DPA
DTA
200 300* 400 300 600
Nominal power output 200 W 300 W 400 W 300 W 600 W
Temperature class T4 T3 T3 T4 T3
Height 225 mm 325 mm

 * This Heater type is also available with the TS40 protective thermostat integrated into the supply cable to keep the temperature up to 40 ° C.
    Ambient temperature control must be carried out using an additional TAE thermostat or TC temperature controller.
(Other types upon request)

6. Options

 AM  Failure alarm opening at < 5 °C
 3M  Supply cable length 3m
 120 V  Nominal voltage 120V AC
 250 V  Nominal voltage 250V AC (245-265 V AC)

Ordering example: CP MEGATHERM DTA 600 T3 3M

7. Installation and minimum clearances

 

8. Wiring diagram


Files to download

Declarations of Conformity

This website uses cookies to ensure you get the best experience on our website.